HYPERPC AMPERE XR ULTRA

8 GPUs in 4U. Liquid cooling. No external CDU.

A high-density barebone platform for on-premises AI, model training, and high-performance computing. It fits into a standard server room and scales from 2 to 8 accelerators.

HYPERPC AMPERE XR ULTRA

8 GPUs in 4U. Liquid cooling. No external CDU.

A high-density barebone platform for on-premises AI, model training, and high-performance computing. It fits into a standard server room and scales from 2 to 8 accelerators.

8 GPU
in a single chassis
700 W
per slot
8000 W
continuous load
4U
standard rack
No CDU
closed loop
01 / PLATFORM

Not an off-the-shelf box, but the foundation of your solution

AMPERE XR ULTRA provides a proven barebone platform in which the chassis, power system, and liquid cooling loop work as a single system. The integrator selects the motherboard, processors, GPUs, memory, storage, and networking to match the workload.

Motherboard agnostic

EATX, EEB, CEB, and TEB. AMD SP5 or Intel LGA 4677 / 4710.

From 2 to 8 GPUs

Start with your current workload and expand the system without replacing the chassis.

Built in Slovenia

Engineering assembly and cooling-loop testing in Komenda, Slovenia.

02 / WHY OWN YOUR SERVER

Control where the cloud falls short

An on-premises platform puts your team back in control of budgets, data, latency, and the experimentation environment.

Industry leaders

We use only the most advanced technologies

Data sovereignty

Models and datasets remain within your infrastructure.

Minimal latency

Your team controls the data, network, and compute resources.

Secure sandbox

An isolated environment for testing, fine-tuning, and R&D.
03 / DENSITY AND THERMALS

8 GPUs without compromising cooling

Single-slot water blocks free up space inside the 4U chassis, while a unified loop removes heat from the GPUs and CPUs under sustained full load.

Eight graphics cards in the AMPERE XR ULTRA liquid cooling loop

Validated with 8 × NVIDIA H200 NVL

Testing at an ambient temperature of 30 °C confirmed stable thermals under full load. Final values depend on the selected components and server-room conditions.

  • Up to 700 W of continuous power per slot
  • Up to 8000 W of continuous platform power
  • No external CDU or connection to the building water supply
76–81 °C
GPU package at 30 °C ambient
36–39 °C
measured DRAM temperature
76 dB(A)
measured noise level
04 / CLOSED LOOP

All cooling is contained within 4U

The pump, manifold, radiator, reservoir, and water blocks form a pre-filled, tested loop. Quick-disconnect fittings allow individual components to be serviced without dismantling the entire system.

Closed-loop liquid cooling inside the 4U chassis
05 / POWER AND SERVICE

Platform-grade reliability

The power system and cooling loop are engineered at the chassis level for high-density workloads, redundancy, and servicing without prolonged downtime.

Five redundant 2000 W power supplies

5 × 2000 W Titanium

Redundant power supplies and a dedicated PDU deliver power to the platform independently of the motherboard VRM. Maximum continuous chassis power is up to 8000 W.

  • 80 PLUS Titanium and redundancy
  • Up to 700 W continuous power per GPU slot
  • 5 × 2.5-inch drive bays

Replace a GPU without dismantling the entire loop

Quick-disconnect fittings isolate the required component. The service station performs a complete cycle of leak testing, draining, cleaning, flushing, vacuum filling, and inspection.

Only the approved EK-CryoFuel engineered coolant is used.

An engineer servicing the server's liquid cooling loop
01  Leak test
02  Drain
03  Clean
04  Flush
05  Vacuum fill
06  Done
06 / SCALING

Start with 2 GPUs. Scale up to 8.

One platform supports every stage of team maturity, from departmental inference to production AI and HPC.

Internal layout of the AMPERE XR ULTRA platform
2 GPU

Department


2 × RTX 6000 Ada
1 × AMD EPYC 9354
256 GB ECC

Inference, visualization, and initial on-premises models

4 GPU

Research group


4 workstation/HPC-class GPUs
Dual-socket platform
512 GB ECC

Shared research and fine-tuning environment

8 GPU

Enterprise AI


8 × NVIDIA H200 NVL
2 × Xeon Platinum 8580
1 TB ECC

Training, large models, and HPC workloads

The configurations shown are for guidance only. Compatibility, cooling, and final continuous power are validated for each project before a proposal is issued.

07 / COMPLETE SOLUTION

The AMPERE XR ULTRA platform. A HYPERPC solution.

Clearly divided responsibilities preserve component flexibility while giving the customer a single point of contact for design, integration, and support.

LM TEK

Platform engineering

  • Chassis, PDU, and redundant power
  • Pre-filled liquid cooling loop
  • Compatibility and thermal-capacity validation

HYPERPC

Complete server design

  • Selection of CPU, GPU, memory, networking, and storage
  • Assembly, burn-in testing, and software stack configuration
  • Deployment, ongoing support, and a unified SLA
08 / SPECIFICATIONS

The platform's technical foundation

Barebone platform specifications. The final specification is confirmed after the selected BOM has been validated.

Parameter Specification
Form factor 4U, 19-inch rack
Dimensions and weight 760 × 482 × 178 mm; approximately 38 kg in barebone configuration
GPU Up to 8 full-size PCIe Gen 5 GPUs; up to 700 W continuous power per slot
Power 5 × 2000 W 80 PLUS Titanium, redundant; up to 8000 W sustained
Motherboards EATX / EEB / CEB / TEB
Processor platforms AMD SP5; Intel LGA 4677 / 4710 / 4710-2
Memory and storage Depends on the selected motherboard, typically up to 24 DDR5 RDIMMs; 5 × 2.5-inch drives
Cooling Closed loop within the chassis, EK-CryoFuel, quick-disconnect fittings; no external CDU required
Operating conditions Air: 5–30 °C; coolant: 5–60 °C
SKU / manufacturing 3831129902367; engineered & assembled in Komenda, Slovenia
Important: motherboard, CPU, GPU, RAM, storage drives, and network cards are not included. Adequate rack power and sufficient room-cooling capacity are required. The maximum ratings of 700 W per slot and 8000 W depend on the selected components and ambient temperature.
09 / FAQ

Frequently asked questions about the platform

Key engineering requirements are clarified during the configuration design stage.

  • Is an external CDU required?
  • Can I start with 2 GPUs?
  • Which accelerators are supported?
  • What is included in the barebone platform?
  • How is the liquid cooling loop serviced?
  • What are the server-room requirements?

We will configure the platform for your model and infrastructure

We will define the workload, available rack power, and GPU and storage requirements, then provide a validated BOM and deployment plan.

Need a consultation?

You are viewing: HYPERPC AMPERE XR ULTRA 8-GPU Server Solution
To request personalized pricing, please complete the form:

Contact Us
Contact Us
Every HYPERPC computer is the result of 15 years of experience and expertise. Our experts know exactly what a gaming PC, workstation, or server should be like.
To get started, we just need to talk. Tell us about your tasks, timelines, and budget, and we will offer the best solution.
Call us or request a callback:
Message us:
Send an email:
sales@hyperpc.ae
Need to quickly know the cost?
Working hours: Daily from 10 AM to 7 PM.
English
+971 4 526 3600
Dayly from AM 10:00 to 7:00 PM